Filter Results By:

Products

Applications

Manufacturers

Showing results: 46 - 60 of 379 items found.

  • PXI/PXIe Analog Output/Current Loop Simulator Module - 4 Channel

    43-765-004 - Pickering Interfaces Ltd.

    The 41/43-765-004 is an 4-channel Analog Output Module designed to meet the requirements of industrial control applications utilising current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signalling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.

  • PXI/PXIe Analog Output/Current Loop Simulator Module - 16 Channel

    43-765-001 - Pickering Interfaces Ltd.

    The 41/43-765-001 is a PXI/PXIe 16-channel Analog Output Module designed to meet the requirements of industrial control applications utilising current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signalling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.

  • PXI/PXIe Analog Output/Current Loop Simulator Module - 12 Channel

    43-765-002 - Pickering Interfaces Ltd.

    The 41/43-765-002 is a 12-channel Analog Output Module designed to meet the requirements of industrial control applications utilising current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signalling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.

  • PXI/PXIe Analog Output/Current Loop Simulator Module - 8 Channel

    43-765-003 - Pickering Interfaces Ltd.

    The 41/43-765-003 is an 8-channel Analog Output Module designed to meet the requirements of industrial control applications utilising current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signalling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.

  • PCI-6704, 16‑Bit, 32‑Channel, Static Analog Output Device

    777306-01 - NI

    The PCI‑6704 is a static analog output device that you can use for software‑timed voltage and current output applications.

  • PXIe-4163, 24-Channel, ±24 V, 50 mA PXI Source Measure Unit

    784483-01 - NI

    PXIe, 24-Channel, ±24 V, 50 mA PXI Source Measure Unit—The PXIe-4163 is a high-density source measure unit (SMU). It features 4-quadrant operation with a current resolution of 100 pA and the ability to sample up to 100 kS/s. The module also offers the ability to maximize stability and measurement accuracy with SourceAdapt, which allows you to custom-tune the transient response to match the characteristics of any load. The PXI-4163 is ideal for a broad range of mixed-signal integrated circuits (ICs) in semiconductor production test.

  • PXIe-4162, 12-Channel, ±24 V, Precision PXI Source Measure Unit

    785680-01 - NI

    PXIe, 12-Channel, ±24 V, Precision PXI Source Measure Unit - The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog-to-digital converter technology to help you perform high-precision measurements. It also features guard terminals to remove the effects of leakage currents and parasitic capacitances. Additionally, the PXIe-4162 can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. The PXIe-4162 is ideal for a broad range of mixed-signal integrated circuits (ICs) in semiconductor production test.

  • PXIe-4353, 32-Channel, 24-Bit PXI Temperature Input Module

    781348-01 - NI

    32-Channel, 24-Bit PXI Temperature Input Module—The PXIe‑4353 is a thermocouple input module that provides integrated data acquisition and signal conditioning for temperature measurements. The PXIe‑4353 includes increased accuracy and synchronization features for scalable measurement systems from low‑ to high‑channel counts. The high accuracy is attributed to the NI TB‑4353 isothermal terminal block that optimizes thermal conductivity between the thermocouple terminals and the cold-junction compensation (CJC) channels. The PXIe‑4353 has two auto zero channels for offset compensation as well as open thermocouple detection to identify disconnected thermocouples.

  • PXIe-4481, 24-Bit, 6-Channel, 1.25 MS/s/ch PXI Analog Input Module

    784278-01 - NI

    24-Bit, 6-Channel, 1.25 MS/s/ch PXI Analog Input Module—The PXIe‑4481 is an analog input module for higher bandwidth voltage measurements. The module offers analog and digital filtering for accurate frequency domain measurements. You also can select from four gain settings to configure your input range. For measuring sudden changes, such as high speed blast and pressure events, the PXIe-4481 can sample up to 20 MS/s per channel in time domain mode. The included NI-DAQmx driver simplifies hardware configuration and measurement.

  • PXIe-4330, 25 kS/s, 24-Bit, 8-Channel PXI Strain/Bridge Input Module

    781346-01 - NI

    25 kS/s, 24-Bit, 8-Channel PXI Strain/Bridge Input Module—The PXIe‑4330 is a simultaneous input module that provides integrated data acquisition and signal conditioning for bridge-based sensors. The PXIe‑4330 includes increased accuracy, high data throughput, and synchronization features, making it ideal for high-density measurement systems. To remove noise, the PXIe‑4330 offers antialiasing and digital filters per channel. Each channel also features an independent, programmable excitation voltage. Additionally, the PXIe‑4330 provides remote sensing, internal bridge completion, and shunt calibration options per channel.

  • PXIe-4480, 1.25 MS/s, 3.4 Hz AC/DC-Coupled, 6-Input PXI Sound and Vibration Module

    784277-01 - NI

    1.25 MS/s, 3.4 Hz AC/DC-Coupled, 6-Input PXI Sound and Vibration Module—The PXIe‑4480 is designed for high-bandwidth audio, acoustic, and vibration measurements. It provides six channels of dynamic signal acquisition, and you can use one of four gain settings to configure your input range. The PXIe‑4480 also includes software-configurable AC/DC coupling, charge measurement, voltage excitation, IEPE excitation, and TEDS support, making it ideal for measuring acoustic transducers, pressure sensors, and hydrophones. Common applications include audio test; noise, vibration, and harshness (NVH) analysis; and underwater acoustic measurements. For measuring sudden changes, such as high speed blast and pressure events, the PXIe-4480 can sample up to 20 MS/s per channel in time-domain mode.

  • PXIe-4339, 25 kS/s, 24-Bit, 8-Channel PXI Strain/Bridge Input Module

    783531-01 - NI

    25 kS/s, 24-Bit, 8-Channel PXI Strain/Bridge Input Module—The PXIe‑4339 is a universal bridge input module ideal for test cell installations requiring both accuracy and flexibility. Completely configurable through software, each channel can take bridge-based measurements and direct voltage measurements. Eight input ranges in ratiometric mode and four in voltage mode accommodate a wide variety of sensor types for your changing application needs. The PXIe‑4339 also features per-channel wide bandwidth analog outputs, programmable excitation, Transducer Electronic Data Sheet (TEDS) support, and digital filtering.

  • PXIe-4322, 16-Bit, 8-Channel, 250 kS/s Ch-Ch Isolated PXIe Analog Output Module

    782878-01 - NI

    16-Bit, 8-Channel, 250 kS/s Ch-Ch Isolated PXIe Analog Output Module—The PXIe‑4322 is a channel‑to‑channel isolated analog output module with integrated signal conditioning. The device provides accurate, simultaneous dynamic voltage and current outputs. By combining signal conditioning and D/A converters on the same device, the PXIe‑4322 isolated analog output module delivers a smaller footprint and higher measurement performance. In current mode, the module operates in all four quadrants, so you can both sink and source current. Isolation and higher voltage and current outputs make this module ideal for automotive applications.

  • PXIe-4309 , 28-Bit, 32-Channel, 2 MS/s, ±15 V Flexible Resolution PXI Analog Input Module

    784471-01 - NI

    28-Bit, 32-Channel, 2 MS/s, ±15 V Flexible Resolution PXI Analog Input Module—The PXIe-4309 samples up to 32 differential channels and multiplexes the analog input channels across eight simultaneously sampling ADCs. The module samples eight input channels up to 2 MS/s/ch (single channel per ADC), and 32 input channels up to 100 kS/s/ch (four channels per ADC). The module's flexible resolution ranges from 18 bits at 2 MS/s/ch to 28 bits at 2 S/s/ch. The module features on-board signal averaging and filtering, auto-zero measurement switching, and a chopping mode that uses a pair of channels to provide high levels of noise rejection and to enable accurate and repeatable nano-volt measurements.

  • PXI-4461, 204.8 kS/s, 2-Input/2-Output PXI Sound and Vibration Module

    779687-01 - NI

    204.8 kS/s, 2-Input/2-Output PXI Sound and Vibration Module—The PXI‑4461 is designed for sound and vibration applications. It provides two-channel dynamic signal generation and two-channel acquisition, and you can use one of six gain settings to configure your input range. The PXI‑4461 also includes software-configurable AC/DC coupling and IEPE conditioning. The PXI‑4461 includes the hardware and software needed to make precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. Common applications include audio test; automotive noise, vibration, and harshness (NVH); and machine condition monitoring.

Get Help